Before you spend a dollar on a basement apartment, grab a tape measure. Ceiling height is the rule that stops more basement units than any other.
The numbers
- Living areas: at least 1.95 m, about 77 inches (6'5") of clear height over the required area of each room.
- Under beams, ducts and bulkheads: no lower than about 1.85 m, roughly 72 to 73 inches (6'1").
These are the Ontario Building Code minimums commonly applied to second units in existing houses. Measure from the finished floor to the finished ceiling, so allow for flooring and drywall.
How to measure it yourself
- Measure from the concrete floor to the underside of the floor joists.
- Subtract about 1.5 inches for flooring and subfloor, and about 0.5 inch for drywall.
- Now measure under the lowest duct or beam and subtract the same.
What if it's too low?
- Move ducts and pipes into the joist spaces to raise bulkheads.
- Lower the floor with underpinning or a bench footing. This is a bigger job, priced separately.
- Change the layout so low areas become storage or mechanical space.
Newer homes built in the last 15 years usually pass easily. Older bungalows often don't. Either way, we measure during a free review and tell you straight. Read the full minimum requirements.